Microvolume Spectrophotometer

OPTIZEN NanoQ Lite is a small micro sample analyzer with a simple yet sophisticated design and easy and convenient user interface (UI).

It applies the Slope Algorithm, which is a light path optimization technique, to enable measurement of a wide range of absorbance.

Main Charateristics

  • It can measure protein and conduct cell counting.
  • The measurement result can be saved or downloaded to a USB flash drive or smartphone.
  • A user can easily operate the system using the intuitive LCD screen and touch functions.
  • It does not need a separate computer since the main unit performs the control.
  • The measurement data can be saved in the equipment to improve the spatial utilization and economic efficiency.
  • The lightweight and small spectrophotometer features the dimensions of 148 x 179 x 110 mm and weight of 1.4 kg.
  • The built-in touch LCD panel helps users operate it easily and conveniently.

Product Qualification

Instrument TypeMicrovolume Spectrophotometer
Minimum Sample Volume1 μL
Sample Number1
Pathlength0.03 ~ 0.5 mm (Auto ranging)
Spectral Resolution≤ 8.0 nm
Absorbance Precision0.002 Abs (0.5 mm pathlength)
Absorbance Range0 – 40 Abs
Detection LimitAbout 2 ng/μL (dsDNA)
Maximum Concentration2,000 ng/µL (dsDNA), 60 mg/ml (BSA), 28.8 mg/ml (IgG)
Photometric Range(10 mm Equivalent)Cuvette: 0~2 A
Photometric Accuracy3% (at 1A/mm at 280 nm)
Light SourceLEDs
Measurement Wavelenght260, 280 nm / 600 nm(Cuvette)
Baseline Correction Wavelenght360 nm
DetectorSilicon photodiode
Measurement Time‹10 seconds
Footprint(W × D)145 x 190 mm
Weight1.4 kg
Operating Voltage12 V (DC)
Power ConsumptionOperating – 4.7~5.2 W, Standby – 3.3 W
Display4.3-inch, Touch-screen glove compatible
Display resolution480 x 272 pixels (Color display)
Internal Storage4 GB
ConectivityUSB-A, USB-B, RS232C
AccessoriesThermal Printer(Optional)


* The contents of this document may be changed without notice.

  • Product detailsUsing three LED (260 nm, 280 nm, and 600 nm) and a single silicon photodiode, it lowered the product cost drastically while maintaining the needed functions and performance level.

    It can perform the baseline correction function using an additional LED (360 nm).
    There is no need for a user manual since it provides a simple and intuitive user environment. The designated factor is set as the default value for each mode, and the input mode is provided to allow the users to set a factor value which is different from the default.

    Users can specify the factor appropriate for the user preference, the lab environment, and the type of protein.